▍Specification
Model |
PU-30 |
PU-30S |
PU-50 |
PU-50S |
Sensing method |
Through-beam |
Sensing distance |
30 mm |
50 mm |
Sensing object |
Ø2 ㎜ min
(Opaque body)
|
Ø0.6 ㎜ min
(Opaque body)
|
Ø1.5 ㎜ min
(Opaque body)
|
Ø0.4 ㎜ min
(Opaque body)
|
Power supply voltage |
12 - 24 V d.c. ± 10 % |
Current consumption |
30 ㎃ max |
Control output |
NPN Voltage output, Load current : 200 ㎃ (30 V d.c.) max, Remaining voltage : 2 V d.c. max |
Output action |
L.ON/D.ON selected by the power reverse connection |
Response time |
1 ㎳ max |
Light source (wave length) |
Infrared LED |
Operation Lamp |
Operation Indicator : Red LED, Power Indicator : Green LED |
Sensitivity adjustment |
Fixed |
By the volume |
Fixed |
By the volume |
Protective circuit |
Output short protective circuit |
Ambient illumination |
▪Sunlight : 11,000 Lux max ▪Incandescent lamp : 3,000 Lux max |
Ambient temperature |
operating temperature : -20 ~ 60 ℃ During storage : -25 ~ 70 ℃ (Without condensation or icing)
|
Ambient humidity |
35 ~ 85 % RH (With no condensation) |
Protective structure |
IP 65 (IEC) |
Insulation resistance |
More than 20 MΩ (500 V d.c. mega) |
Dielectric strength |
1,000 V a.c. (50/60 Hz for 1 minute) |
Vibration resistance |
10 - 55 ㎐ double amplitude 1.5 ㎜, for 2 hours each in X · Y · Z directions |
Shock resistance |
500 m/s², 3 times each in X · Y · Z directions |
Connection method |
Cable withdrawal type (number of wires : 3P, outer diameter : Ø4 ㎜, length : 2 m)
|
Material |
Case : ZN, Lens : PC |
Certification |
|
Weight |
Approx. 250g (Included the weight of box) |
- Please note that response time varies depending on the size of sensing object, surface condition, existence of gloss and etc.
|