▍Specification
|
Display
|
Digit display method
|
|
Model
|
NPN
|
PFD-RGN
|
PFD-RMN
|
|
PNP
|
PFD-RGP
|
PFD-RMP
|
|
Appearance
|
 |
|
Power supply voltage
|
12 - 24 V d.c. ±10 %
|
|
Current Consumption
|
50 mA max.
|
|
Output
|
Main
|
Control : Open collector output, 100 mA (30 V d.c. Residual voltage 1 V or less)
|
|
Sub
|
Stability : Open collector output, 100 mA (30 V d.c. Residual voltage 1 V or less)
|
|
External Input
|
Teaching by external input signal
|
Teaching / Reset input
|
|
Mtensity of light
|
0~1,000
|
|
Multi
functions
|
Counter
|
-
|
400 cps, Up/Down, 0~9,999
|
|
RPM
|
-
|
12 ~ 9,999 rpm
|
|
Output action
|
Light On / Dark On Output
NORMAL , ON DELAY, OFF DELAY, ONE Shot Time Output
|
|
On/Off Delay
|
0 ~ 9,999 ms
|
|
OneShotTime
|
0 ~ 9,999 ms
|
|
Light source
(wave length)
|
Red LED / 660 nm
|
|
Protective circuit
|
Built in the reversed power supply connection protective circuit and output short
protective circuit
|
|
Response time
|
0.7 ms max
|
1 ms max
|
|
The Rate of Change
|
10 % max
|
|
LED
|
7 contacts state indicating LED, 7 segments LED 4 digits
|
|
Sensitivity adjustment
|
Auto teaching / Manual setting by using the set button
|
|
Additional Function
|
Display brightness control function & 180-degree rotating display
Display time setting, Lock function
|
Display brightness control function & 180-degree rotating display
Display time setting, Zero Reset, Initial Reset, Lock function
|
|
Ambient illumination
|
Sunlight : 10,000 lx max, Incandescent lamp : 3,000 lx max
|
|
Ambient temperature
|
In opration : -10 ℃ ~ 55 ℃, In storage : -25 ℃ ~ 70 ℃ (without condensation or freezing)
|
|
Ambient humidity
|
35 ~ 85 % RH
|
|
Vibration resistance
|
10 - 55 ㎐ double amplitude 1.5 mm, for 2 hours each in X · Y · Z directions
|
|
Shock resistance
|
500 m/s² 3 times each in X · Y · Z directions
|
|
Dielectric strength
|
Max 1 minute in 1000 V a.c. (50 - 60 ㎐)
|
|
Insulation resistance
|
Min 20 MΩ in 500 V d.c.
|
|
Connection method
|
▪DIN rail installation structure,
▪Code extended type,
▪Code length : 2 m,
▪No. of lines : 5P,
▪Thickness : Ø4 mm
|
|
Accessory
|
Mounting bracket
|
|
Certification
|
|
■ Multi-functions
|
Multi
functions
|
Counter
|
▪UP / DOWN mode, Free scale 1~999 (double, demultiply setting)
▪Range : 0 - 9,999 ▪Counting speed : 400 cps (50 % duty)
▪Output mode : N, F, C, R, K, P, Q, A 8 kinds
▪External reset : Min. signal width 5 ㎳
|
|
RPM
|
▪Range : 0 - 9,999 rpm
▪Speed guard output
▪Free scale : 1 - 1,000 Measring
▪Cycle setting
|
- Cautions) Use by combining the Fiber Unit in the form of transmission type at the time of
Tachometer/Count Measurement. Malfunction can occur from the increase in the light receiving change
range by speed when using for the reflection purpose. Distance measurement at the optical
measurement mode changes in accordance with the Fiber Cable and within 20 mm is recommended.
|