▍Specification
Model
FS-3 A(High sensitivity)
FS-3 A(Low sensitivity)
Power supply Voltage
110 V a.c. / 220 V a.c. 50/60 Hz
Allowable voltage
fluctuation range
±10 % of the power supply voltage
Voltage
between the
electrodes
secondary voltage
24 V a.c.
8 V a.c.
Power consumption
Approx. 3.2 VA
Response time
Max 80 ㎳ when operating, max 160 ㎳ when returning
Operration resistance
between electrodes
0 - approx. 27 KΩ
0 - approx. 7 KΩ
Return resistance
between electrodes
approx. 38 KΩ - ∞ Ω
approx. 15 KΩ - ∞ Ω
Control output
Relay contact output (1c) : 250 V a.c 5 A (Resistive load)
Insulation resistance
100 ㏁ min (With 500 V d.c mega) electric conduction part and exposed non-charged metal part
Dielectric strength
2000 V a.c 50 - 60 ㎐ for 1 min
(Between the two poles recharging part terminal)
Vibration resistance
10 - 55 ㎐ (For cycle 1 min) Peak amplitude for 2hrs each in X, Y and Z direction 0.76 ㎜
Shock resistance
approx. 300 m/s²
Life expectancy
Mechanically more than 5 million times (Relay type)
Electrically more than 500 thousand times (Load resistance)