HY-M900/HY-LM900 series Aluminum die cast case
- Solid die casting case and built in the 2 circuits double micro switch
- High mechanical intensity with the heat resistance,
  oil proof and dust protection structure
- Various actuators (8 types) provide wide application
- IP67 protective structure (when using the company product HYC-M1 in wire opening)
- Check the operation state on the outside by attaching the operation indicator.
CERUCCCEK

The order from the left is the order in which the information is displayed at the bottom. If you cancel the check, the information will be excluded, and if you check, it will be printed out.

print_icon

Specification

Model

HY-M902

HY-LM902

HY-M903

HY-LM903

Shape

M902 LM902 M903 LM903

Type

Roller Plunger type

Ball Plunger type

Model

HY-M904

HY-LM904

HY-M907

HY-LM907

Shape

M904 LM904 M907 LM907

Type

Roller Adjustable Lever type

Adjustable Rod Lever type

Model

HY-M908

HY-LM908

HY-M909

HY-LM909

Shape

M908 LM908 M909 LM909

Type

Roller Lever type

Coil Spring type

Model

HY-M908R

HY-M908L

Shape

M908R M908L

Type

Ø50 Roller Lever type

Fork Roller Lever type

Common specification

Allowable operating speed

0.1 - 1 m/s

Open/close

frequency

Mechanical

120 times/min

Electrical

20 times/min

Insulation resistance

100 MΩ min (500 V d.c.)

Dielectric strength

1,000 V a.c. 50/60 ㎐ for 1 min (among terminals)

1,500 V a.c. 50/60 ㎐ for 1 min (among unfilled metal parts)

Contact resistance

Max. 100 mΩ (initial value)

Vibration

resistance

Malfunction

10 - 55 ㎐ double amplitude 1.5 ㎜

Shock

resistance

Mechanical

1,000 m/s² min (100 G min)

Malfunction

300 m/s² min (30 G min)

Life

Mechanical

1,000,000 times min

Electrical

300,000 times min

Ambient temperature and humidity

-10 ~ 80 ˚C, 45 ~ 95 % R.H

Approval

CE  RU  CCC  KC

Weight

Approx. 350 g (HY-M904, box included)