▍Specification
|
Model
|
TPS-15S
|
TPS-30S
|
TPS-50S
|
TPS-75S
|
|
Appearance
|
|
|
|
|
|
W × H × D (㎜)
|
64.1x97.6x32.0
|
79.0x98.0x37.0
|
83.0x125.0x38.8
|
96.0x135.0x40.2
|
|
Power output
|
15 W
|
30 W
|
50 W
|
75 W
|
|
Input voltage
|
Free voltage 100-240 V a.c. (50/60 ㎐)
|
|
Output voltage
|
5 V, 12 V, 15 V, 24 V d.c.
|
|
Voltage fluctuation range
|
±5 ~ ±10 % (Varies due to the internal VR)
|
|
Protective circuit
|
Overcurrent, Overvoltage, Overheating, Output short-circuit protection
|
|
Dielectric strength
|
• 2,700 V a.c. 1 minute, detection current = 10 ㎃, (input-output)
• 1,500 V a.c. 1 minute, detection current = 10 ㎃, (input-FG)
• 500 V a.c. 1 minute, detection current = 10 ㎃, (output-FG)
|
|
Insulation resistance
|
100 ㏁ min, 500V d.c. (Input - Output)
|
|
Model
|
TPS-100S
|
|
Appearance
|
 |
|
W × H × D (㎜)
|
93.0x199.0x50.0
|
|
Power output
|
100 W
|
|
Input voltage
|
Manual-select input 100 - 120V a.c. 50/60 ㎐ / 200 - 240 V a.c. 50/60 ㎐
|
|
Output voltage
|
5 V, 12 V, 15 V, 24 V d.c.
|
|
Voltage fluctuation range
|
±5 ~ ±10 % (Varies due to the internal VR)
|
|
Protective circuit
|
Overcurrent, Overvoltage, Overheating, Output short-circuit protection
|
|
Dielectric strength
|
• 2,700 V a.c. 1 minute, detection current = 10 ㎃, (input-output)
• 1,500 V a.c. 1 minute, detection current = 10 ㎃, (input-FG)
• 500 V a.c. 1 minute, detection current = 10 ㎃, (output-FG)
|
|
Insulation resistance
|
100 ㏁ min, 500V d.c. (Input - Output)
|
|
Model
|
TPS-150S
|
TPS-220S
|
TPS-350S
|
|
Appearance
|
 |
 |
 |
|
W × H × D (㎜)
|
93.0x209.0x65.0
|
93.0x209.0x65.0
|
115.0x230.0x50.0
|
|
Power output
|
150 W
|
220 W
|
350 W
|
|
Input voltage
|
Manual-select input
100 - 120 V a.c. 50/60 ㎐ / 200 - 240 V a.c. 50/60 ㎐
|
|
Output voltage
|
5 V,12 V,15 V,24 V d.c.
|
12 V, 15 V, 24 V d.c
|
12 V, 24 V, 48 V d.c.
|
|
Voltage fluctuation range
|
±5 ~ ±10 % (Varies due to the internal VR)
|
|
Protective circuit
|
Overcurrent, Overvoltage, Overheating, Output short-circuit protection
|
|
Dielectric strength
|
• 2,700 V a.c. 1 minute, detection current = 10 ㎃, (input-output)
• 1,500 V a.c. 1 minute, detection current = 10 ㎃, (input-FG)
• 500 V a.c. 1 minute, detection current = 10 ㎃, (output-FG)
|
|
Insulation resistance
|
100 ㏁ min, 500V d.c. (Input - Output)
|
|
Model
|
TPS-100S
|
|
Appearance
|
 |
|
W × H × D (㎜)
|
115.0x230.0x50.0
|
|
Power output
|
450 W
|
|
Input voltage
|
Free voltage 100 - 240 V a.c. 50/60 ㎐
|
|
Output voltage
|
12 V, 24 V, 48 V d.c.
|
|
Voltage fluctuation range
|
±5 ~ ±10 % (Varies due to the internal VR)
|
|
Protective circuit
|
Overcurrent, Overvoltage, Overheating, Output short-circuit protection
|
|
Dielectric strength
|
• 2,700 V a.c. 1 minute, detection current = 10 ㎃, (input-output)
• 1,500 V a.c. 1 minute, detection current = 10 ㎃, (input-FG)
• 500 V a.c. 1 minute, detection current = 10 ㎃, (output-FG)
|
|
Insulation resistance
|
100 ㏁ min, 500V d.c. (Input - Output)
|
|