CV250 Temperature / Humidity converters
· DIN rail and bolt fixing mounting method
· Uniform with DC signal
· Relative humidity calculation by dry bulb temperature and wet bulb temperature
· Two-wire transmission line is simple.
· Simple signal distribution (low output resistance)
· Linear signal

The order from the left is the order in which the information is displayed at the bottom. If you cancel the check, the information will be excluded, and if you check, it will be printed out.

print_icon

▍Specification

Power supply

100 - 240 V a.c., 50 - 60 ㎐

Power consumption

3 VA Max.

Input

R.T.D Pt100 Ω (IEC751) (Dry bulb : 1 contact, Wet bulb : 1 contact)

Measuring range

Temperature : 0 ~ 100 ℃ / Humidity : 0 ~ 100 %R.H

Accuracy

Temperature : ± 0.5 % / Humidity : ±1 % R.H

Output

4 - 20 ㎃ (Resistive load : 600 Ω Max.) or

1 - 5 V (Resistive load : 1 kΩ Min)

Output compensation

Offset compensation by variable resistance ±5 % (Temp. & Humidity)

Operating ambient temperature

0 ~ 50 ℃

Dimension

39 x 81 x 82 ㎜ (W x L x H)