▍Specification
|
Model
|
Low
|
HSR-2SLD252Z
|
HSR-2SLD402Z
|
|
High
|
HSR-2SLD254Z
|
HSR-2SLD404Z
|
|
Load
|
Rated LoadVoltage
|
Low
|
90 - 264 V a.c.
|
|
High
|
90 - 480 V a.c.
|
|
Voltage
|
Low
|
600 V
|
|
High
|
1200 V
|
|
Rated load current
|
25 A
|
40 A
|
|
Frequency
|
50/60 Hz (Dual usage)
|
|
Surge current
(8.3 ms No repetition)
|
Low
|
260 A
|
420 A
|
|
High
|
250 A
|
370 A
|
|
Leakage current
|
10 ㎃ max
|
|
Output ON voltage dropping
|
1.8 V (R.M.S) max
|
|
Rated impulse
withstand voltage
|
Low
|
4 ㎸
|
|
High
|
6 ㎸
|
|
Input
|
Rated Voltage
|
5 - 24 V d.c.
|
|
Operating Voltage Range
|
4 - 32 V d.c.
|
|
Impedance
|
Less than 4 ㏀
|
|
Operation Voltage
|
More than 3 V DC
|
|
Reset Voltage
|
Less than 1.5 V DC
|
|
Input Current
|
Constant-current system : 10 ㎃ (±3)
|
|
Detection parts
|
Rated Voltage
|
24 V d.c.
|
|
Operating Voltage Range
|
20 - 26 V d.c.
|
|
Power consumption
|
Max 25 ㎃, Max 40 ㎃ in case of Alarm output (Base on 24 V DC)
|
|
Collector pressure
|
30 V DC max
|
|
Maximum rated
through current
|
50 ㎃ max
|
|
Max. collector
power consumption
|
500 mW
|
|
Output type
|
Transistor open collector (Hi at detection of problem)
|
|
Response Time
|
1/2 Cycle + 1 ms max. (“R”type below 1 ms)
|
|
Insulating Resistance
|
500 V DC, 100 ㏁ (Between the input / output and case)
|
|
Dielectric strength
|
2,500 V AC (For 1 min at 60 ㎐)
|
|
Vibration resistance
|
10 - 55 ㎐, Double amplitude : 1.5 ㎜, X,Y, and Z direction for 2 hours
|
|
Shock resistance
|
1,000 ㎨, X,Y,Z each axis 3 times
|
|
Storage Temperature
|
-30 ~ 90 ℃
|
|
Ambient Temperature
|
0 ~ 25 ℃ (But without frostiness)
|
|
Ambient Humidity
|
45 ~ 85 % R.H.
|
|
Pollution level grade
|
2 level pollution
|
|
Degree of protection
|
IP20
|
|
Usage
|
Resistive load / Inductive load
|
|
Accepted standard
|
IEC 62314
|
|
Approval
|
|
|
Weight
|
Approx. 1,000 g
|
Approx. 1,300 g
|
|