MT100 LCD Type Mold Temperature Controller
- Communication (RS485/422)
- Displaying and saving abnormal information
- 4 input channels (control : 2 channels, supervise : 2 channels)
- Alarm : detection of temperature, pressure and electric current

The order from the left is the order in which the information is displayed at the bottom. If you cancel the check, the information will be excluded, and if you check, it will be printed out.

print_icon

▍Specification

■ Rated specifications

Division

Contents

Power

100 - 240 V a.c.(±10 %) 50/60 Hz

Operating

environment

Temperature

0 ~ 50 ℃

Humidity

45 ~ 85 % R.H.(Without condensation)

Display

128 x 64 MONO LCD

Temperature

Input

Type

Pt 100 Ω, K(CA), J(IC)

Number of Input

4 contacts

Accuracy

± 0.3 % of FS

Sampling Time

1 s

Measurement Range

0 ~ 300 ℃

Pressure Input

Type

Contact input

Number of Input

1 contact

Accuracy

± 3 % of FS

Sampling Time

1 s

Heating Output

Type

Voltage Pulse output : Over 12 V d.c.

Resolution

0.1 % or 16.667 ms of output, whichever is larger

Cooling Output

Type

Contact output of relay : 250 V a.c. 1 A, 30 V d.c. 1 A

Resolution

0.1 % or 16.667 ms of output, whichever is larger

Contact Input

Number of input

Max 8 contacts

ON/OFF Resistance

1 ㏀ ~ 10 ㏀

Contact Output

Number of input

Max 6 contacts

Output Signal

Relay form A contact

Output Rating

250 V a.c. 1 A, 30 V d.c. 1 A

Communication

Protocol

PC-LINK With SUM

Communication Type

RS485/422(2 Line Half Duplex / 4 Line Half Duplex

Max. Distance

1200 m

Max. Connect Unit

31 Units

■ Power specifications

Power supply voltage

100 - 240 V a.c.
(Operating voltage range:± 10 % of rate supply voltage)

Frequency

50/60 Hz

Power consumption

Max 6.5 W

Insulation resistance

Above 20 MΩ at 500 V d.c.

Dielectric strength

Measuring terminal - earth terminal : 2300 V a.c. for 1 minute
Power terminal - earth terminal : 2300 V a.c. for 1 minute
Measuring terminal - power terminal : 2300 V a.c. for 1 minute

■ Temperature input specifications

Number of input

4 contacts

Input type

Pt 100 Ω, K(CA), J

Sampling period

1 s

Measurement range

0 ~ 300 ℃

Measurement accuracy

(± 0.3 % of F.S)± 1 = digit

Input filter

0 ~ 100 s

Input compensation

- 100 ~ 100 % of F.S

Input resistance

About 1 MΩ

Reference contact
compensation error

Max ± 1.5 ℃

■ Pressure input specifications

Number of inputs

1 contacts

Input type

Contact input

Sampling cycle

1 s

Measurement accuracy

(± 0.3 % of F.S)± 1 digit

■ Voltage PULSE output specification (Heating output)

Number of outputs

1 contact

Output type

Voltage Pulse

Output capacity

MIN. 12 V and over (Over 600 Ω of load resistance)

Resolution

0.1 % or 16.667 ms whichever is larger

■ Relay output specifications

Number of outputs

1 contact

Output type

Relay A contact

Contact capacity

250 V a.c. 1 A, 30 V d.c. 1 A

Measurement accuracy

0.1 % or 16.667 ms whichever is larger

■ Contact input specifications

Number of inputs

8 contact

ON/OFF resistance

1 - 10 kΩ

■ Contact output specifications

Number of outputs

6 contact

Output type

Relay A contact

Contact capacity

250 V a.c. 1 A, 30 V d.c. 1 A

■ Communication specification

Communication connection

2 Line Half Duplex / 4 Line Half Duplex

Max. connection units

31 units

Max. communication distance

1200 m

Communication sequence

None

Communication speed

9600 bps

Start bit

1 bit

Stop bit

1 bit

Data length

8 bits

Parity

None

Protocol

PC-LINK With SUM