- Cooling control and heating control selection
- Alarm output and timer output selection
- ON / OFF and proportional control selection
- 0.1 ℃ / 1 ℃ selection
- Delay output time setting
Suffix codeDimensionPart name and functionConnection diagramControl method for temperatureProportional controlDelay Timer SettingAuxiliary output set and operating descriptionSet mode for normal userEngineer setting modeAdministrator setting mode
The order from the left is the order in which the information is displayed at the bottom.
If you cancel the check, the information will be excluded, and if you check, it will be
printed out.
▍Specification
Input sensor
Company exclusive sensor (TH-540N) ※ Thermistor (NTC)
Input range
-40.0 ~ 90.0 ℃
Display accuracy
± 1 % of FS ± 1 Digit
Control output
Relay output
▪Contact composition : 1 c ▪250 V a.c. ▪5 A (Resistance load)
Voltage Pulse
Output
10 - 15 V d.c. (load resistance 500 Ω or more)
Electric current
Output
4-20 mA d.c. (load resistance 500 Ω or less)
Auxiliary/Defrost
Relay
▪Contact composition : 1 c ▪250 V a.c. ▪5 A (Resistive load)
Control operation
Selection of reverse action (heating)/
direct action (cooling) with parameters
Setting method
Digital method by setting, increasing and decreasing keys