Specification
+ Push button switch
|
Model
|
Flat Ø30
|
Flat Ø25
|
Protrusion Ø30
|
Protrusion Ø25
|
|
Appearance
|
|
|
|
|
|
Actuator code
|
CRF-F30
|
CRF-F25
|
CRF-P30
|
CRF-P25
|
+ Illuminated pushbutton switch
|
Model
|
Flat Ø30
|
Protrusion Ø30
|
Protective guard Ø30
|
|
Appearance
|
|
|
|
|
Actuator code
|
CRX-F30
|
CRX-P30
|
CRX-G30
|
|
Model
|
Flat Ø25
|
Protrusion Ø25
|
Protective guard Ø25
|
|
Appearance
|
|
|
|
|
Actuator code
|
CRX-F25
|
CRX-P25
|
CRX-G25
|
+ Indicator light
|
Model
|
Flat Ø30
|
Flat Ø25
|
|
Appearance
|
|
|
|
Actuator code
|
CRP-30
|
CRP-25
|
+ Selector switch
|
Model
|
Short lever
|
|
Flat Ø30
|
Flat Ø25
|
|
Appearance
|
|
|
|
Actuator code
|
CRS-30
|
CRS-25
|
|
Model
|
Long lever
|
|
Flat Ø30
|
Flat Ø25
|
|
Appearance
|
|
|
|
Actuator code
|
CRSL-30
|
CRSL-25
|
+ Illuminated selector switch
|
Model
|
Flat Ø30
|
Flat Ø25
|
|
Appearance
|
|
|
|
Actuator code
|
CRT-30
|
CRT-25
|
+ KEY selector switch
|
Model
|
Flat Ø30
|
Flat Ø25
|
|
Appearance
|
|
|
|
Actuator code
|
CRK-30
|
CRK-25
|
+ Emergency stop switch
|
Model
|
Flat Ø30
|
Flat Ø25
|
|
Appearance
|
|
|
|
Actuator code
|
CRE-30M
|
CRE-25M
|
|
Model
|
Flat Ø30
|
Flat Ø25
|
|
Appearance
|
|
|
|
Actuator code
|
CRE-30R
|
CRE-25R
|
+ Illuminated emergency stop switch
|
Model
|
Flat Ø30
|
Flat Ø25
|
|
Appearance
|
|
|
|
Actuator code
|
CRA-30M
|
CRA-25M
|
|
Model
|
Flat Ø30
|
Flat Ø25
|
|
Appearance
|
|
|
|
Actuator code
|
CRA-30R
|
CRA-25R
|
+ Buzzer
|
Model
|
Flat Ø30
|
Flat Ø25
|
|
Appearance
|
|
|
|
Actuator code
|
CRB-30
|
CRB-25
|
+ CRF
- Push button switch
|
Model
|
Flat Ø30
|
Flat Ø25
|
Protrusion Ø30
|
Protrusion Ø25
|
|
Appearance
|
|
|
|
|
|
Actuator code
|
CRF-F30
|
CRF-F25
|
CRF-P30
|
CRF-P25
|
- Specification
|
Contact Structure
|
M3.5 Threaded, 1a1b
|
|
Contact Behavior
|
Slow-action
|
|
Installation panel thickness
|
1 ~ 6 mm (Without accessories)
|
|
Terminal Tightening Torque
|
0.8 N·m or less
|
|
Rated voltage
|
250 V a.c.
|
|
Current Rating
|
5A 250 V a.c.
|
|
Open/Close Frequency
|
30 times / minute
|
|
Insulation resistance
|
100 MΩ or more (500 V d.c.)
|
|
Dielectric strength
|
1,500 V a.c. 50/60 Hz 1 minute
|
|
Contact resistance
|
50 mΩ or less (Initial values)
|
|
Vibration resistance
|
10 ~ 55 Hz double amplitude 1.5 mm
|
|
Shock resistance
|
Durability
|
300 m/s² or more (30 G or more)
|
|
Malfunction
|
100 m/s² or more (10 G or more)
|
|
Life
|
Mechanical
|
500,000 times or more
|
|
Electrical
|
100,000 times or more (Rated load)
|
|
LAMP Input Power
|
100 - 240 V a.c. / 4.4 VA or less (Voltage drop type LED capacitor)
380 V a.c. / 2.7 VA or less (Voltage drop type LED capacitor)
12 - 24 V d.c. / a.c. / 18 mA or less (LED resistor voltage dropping method)
|
|
Ambient temperature
|
-20 ~ 55 ℃ (Without condensation or icing)
|
|
Ambient humidity
|
45 ~ 85 % RH
|
|
Preservation ambient temperature
|
-40 ~ 70 ℃
|
|
Certification
|
|
+ CRX
- Illuminated pushbutton switch
|
Model
|
Flat Ø30
|
Protrusion Ø30
|
Protective guard Ø30
|
|
Appearance
|
|
|
|
|
Actuator code
|
CRX-F30
|
CRX-P30
|
CRX-G30
|
|
Model
|
Flat Ø25
|
Protrusion Ø25
|
Protective guard Ø25
|
|
Appearance
|
|
|
|
|
Actuator code
|
CRX-F25
|
CRX-P25
|
CRX-G25
|
- Specification
|
Contact Structure>
|
M3.5 Threaded, 1a1b
|
|
Contact Behavior
|
Slow-action
|
|
Installation panel thickness
|
1 ~ 6 mm (Without accessories)
|
|
Terminal Tightening Torque
|
0.8 N·m or less
|
|
Rated voltage
|
250 V a.c.
|
|
Current Rating
|
5A 250 V a.c.
|
|
Open/Close Frequency
|
30 times / minute
|
|
Insulation resistance
|
100 MΩ or more (500 V d.c.)
|
|
Dielectric strength
|
1,500 V a.c. 50/60 Hz 1 minute
|
|
Contact resistance
|
50 mΩ or less (Initial values)
|
|
Vibration resistance
|
10 ~ 55 Hz double amplitude 1.5 mm
|
|
Shock resistance
|
Durability
|
300 m/s² or more (30 G or more)
|
|
Malfunction
|
100 m/s² or more (10 G or more)
|
|
Life
|
Mechanical
|
500,000 times or more
|
|
Electrical
|
100,000 times or more (Rated load)
|
|
LAMP Input Power
|
100 - 240 V a.c. / 4.4 VA or less (Voltage drop type LED capacitor)
380 V a.c. / 2.7 VA or less (Voltage drop type LED capacitor)
12 - 24 V d.c. / a.c. / 18 mA or less (LED resistor voltage dropping method)
|
|
Ambient temperature
|
-20 ~ 55 ℃ (Without condensation or icing)
|
|
Ambient humidity
|
45 ~ 85 % RH
|
|
Preservation ambient temperature
|
-40 ~ 70 ℃
|
|
Certification
|
|
+ CRP
- Indicator light
|
Model
|
Flat Ø30
|
Flat Ø25
|
|
Appearance
|
|
|
|
Actuator code
|
CRP-30
|
CRP-25
|
- Specification
|
Contact Structure>
|
M3.5 Threaded, 1a1b
|
|
Contact Behavior
|
Slow-action
|
|
Installation panel thickness
|
1 ~ 6 mm (Without accessories)
|
|
Terminal Tightening Torque
|
0.8 N·m or less
|
|
Rated voltage
|
250 V a.c.
|
|
Current Rating
|
5A 250 V a.c.
|
|
Open/Close Frequency
|
30 times / minute
|
|
Insulation resistance
|
100 MΩ or more (500 V d.c.)
|
|
Dielectric strength
|
1,500 V a.c. 50/60 Hz 1 minute
|
|
Contact resistance
|
50 mΩ or less (Initial values)
|
|
Vibration resistance
|
10 ~ 55 Hz double amplitude 1.5 mm
|
|
Shock resistance
|
Durability
|
300 m/s² or more (30 G or more)
|
|
Malfunction
|
100 m/s² or more (10 G or more)
|
|
Life
|
Mechanical
|
500,000 times or more
|
|
Electrical
|
100,000 times or more (Rated load)
|
|
LAMP Input Power
|
100 - 240 V a.c. / 4.4 VA or less (Voltage drop type LED capacitor)
380 V a.c. / 2.7 VA or less (Voltage drop type LED capacitor)
12 - 24 V d.c. / a.c. / 18 mA or less (LED resistor voltage dropping method)
|
|
Ambient temperature
|
-20 ~ 55 ℃ (Without condensation or icing)
|
|
Ambient humidity
|
45 ~ 85 % RH
|
|
Preservation ambient temperature
|
-40 ~ 70 ℃
|
|
Certification
|
|
+ CRS
- Selector switch
|
Model
|
Short lever
|
|
Flat Ø30
|
Flat Ø25
|
|
Appearance
|
|
|
|
Actuator code
|
CRS-30
|
CRS-25
|
|
Model
|
Long lever
|
|
Flat Ø30
|
Flat Ø25
|
|
Appearance
|
|
|
|
Actuator code
|
CRSL-30
|
CRSL-25
|
- Specification
|
Contact Structure>
|
M3.5 Threaded, 1a1b
|
|
Contact Behavior
|
Slow-action
|
|
Installation panel thickness
|
1 ~ 6 mm (Without accessories)
|
|
Terminal Tightening Torque
|
0.8 N·m or less
|
|
Rated voltage
|
250 V a.c.
|
|
Current Rating
|
5A 250 V a.c.
|
|
Open/Close Frequency
|
30 times / minute
|
|
Insulation resistance
|
100 MΩ or more (500 V d.c.)
|
|
Dielectric strength
|
1,500 V a.c. 50/60 Hz 1 minute
|
|
Contact resistance
|
50 mΩ or less (Initial values)
|
|
Vibration resistance
|
10 ~ 55 Hz double amplitude 1.5 mm
|
|
Shock resistance
|
Durability
|
300 m/s² or more (30 G or more)
|
|
Malfunction
|
100 m/s² or more (10 G or more)
|
|
Life
|
Mechanical
|
500,000 times or more
|
|
Electrical
|
100,000 times or more (Rated load)
|
|
LAMP Input Power
|
100 - 240 V a.c. / 4.4 VA or less (Voltage drop type LED capacitor)
380 V a.c. / 2.7 VA or less (Voltage drop type LED capacitor)
12 - 24 V d.c. / a.c. / 18 mA or less (LED resistor voltage dropping method)
|
|
Ambient temperature
|
-20 ~ 55 ℃ (Without condensation or icing)
|
|
Ambient humidity
|
45 ~ 85 % RH
|
|
Preservation ambient temperature
|
-40 ~ 70 ℃
|
|
Certification
|
|
※ Only with CRSL-252A1
|
+ CRT
- Illuminated selector switch
|
Model
|
Flat Ø30
|
Flat Ø25
|
|
Appearance
|
|
|
|
Actuator code
|
CRT-30
|
CRT-25
|
- Specification
|
Contact Structure>
|
M3.5 Threaded, 1a1b
|
|
Contact Behavior
|
Slow-action
|
|
Installation panel thickness
|
1 ~ 6 mm (Without accessories)
|
|
Terminal Tightening Torque
|
0.8 N·m or less
|
|
Rated voltage
|
250 V a.c.
|
|
Current Rating
|
5A 250 V a.c.
|
|
Open/Close Frequency
|
30 times / minute
|
|
Insulation resistance
|
100 MΩ or more (500 V d.c.)
|
|
Dielectric strength
|
1,500 V a.c. 50/60 Hz 1 minute
|
|
Contact resistance
|
50 mΩ or less (Initial values)
|
|
Vibration resistance
|
10 ~ 55 Hz double amplitude 1.5 mm
|
|
Shock resistance
|
Durability
|
300 m/s² or more (30 G or more)
|
|
Malfunction
|
100 m/s² or more (10 G or more)
|
|
Life
|
Mechanical
|
500,000 times or more
|
|
Electrical
|
100,000 times or more (Rated load)
|
|
LAMP Input Power
|
100 - 240 V a.c. / 4.4 VA or less (Voltage drop type LED capacitor)
380 V a.c. / 2.7 VA or less (Voltage drop type LED capacitor)
12 - 24 V d.c. / a.c. / 18 mA or less (LED resistor voltage dropping method)
|
|
Ambient temperature
|
-20 ~ 55 ℃ (Without condensation or icing)
|
|
Ambient humidity
|
45 ~ 85 % RH
|
|
Preservation ambient temperature
|
-40 ~ 70 ℃
|
|
Certification
|
|
+ CRK
- KEY selector switch
|
Model
|
Flat Ø30
|
Flat Ø25
|
|
Appearance
|
|
|
|
Actuator code
|
CRK-30
|
CRK-25
|
- Specification
|
Contact Structure>
|
M3.5 Threaded, 1a1b
|
|
Contact Behavior
|
Slow-action
|
|
Installation panel thickness
|
1 ~ 6 mm (Without accessories)
|
|
Terminal Tightening Torque
|
0.8 N·m or less
|
|
Rated voltage
|
250 V a.c.
|
|
Current Rating
|
5A 250 V a.c.
|
|
Open/Close Frequency
|
30 times / minute
|
|
Insulation resistance
|
100 MΩ or more (500 V d.c.)
|
|
Dielectric strength
|
1,500 V a.c. 50/60 Hz 1 minute
|
|
Contact resistance
|
50 mΩ or less (Initial values)
|
|
Vibration resistance
|
10 ~ 55 Hz double amplitude 1.5 mm
|
|
Shock resistance
|
Durability
|
300 m/s² or more (30 G or more)
|
|
Malfunction
|
100 m/s² or more (10 G or more)
|
|
Life
|
Mechanical
|
500,000 times or more
|
|
Electrical
|
100,000 times or more (Rated load)
|
|
LAMP Input Power
|
100 - 240 V a.c. / 4.4 VA or less (Voltage drop type LED capacitor)
380 V a.c. / 2.7 VA or less (Voltage drop type LED capacitor)
12 - 24 V d.c. / a.c. / 18 mA or less (LED resistor voltage dropping method)
|
|
Ambient temperature
|
-20 ~ 55 ℃ (Without condensation or icing)
|
|
Ambient humidity
|
45 ~ 85 % RH
|
|
Preservation ambient temperature
|
-40 ~ 70 ℃
|
|
Certification
|
|
+ CRE
- Emergency stop switch
|
Model
|
Flat Ø30
|
Flat Ø25
|
|
Appearance
|
|
|
|
Actuator code
|
CRE-30M
|
CRE-25M
|
|
Model
|
Flat Ø30
|
Flat Ø25
|
|
Appearance
|
|
|
|
Actuator code
|
CRE-30R
|
CRE-25R
|
- Specification
|
Contact Structure>
|
M3.5 Threaded, 1a1b
|
|
Contact Behavior
|
Slow-action
|
|
Installation panel thickness
|
1 ~ 6 mm (Without accessories)
|
|
Terminal Tightening Torque
|
0.8 N·m or less
|
|
Rated voltage
|
250 V a.c.
|
|
Current Rating
|
5A 250 V a.c.
|
|
Open/Close Frequency
|
30 times / minute
|
|
Insulation resistance
|
100 MΩ or more (500 V d.c.)
|
|
Dielectric strength
|
1,500 V a.c. 50/60 Hz 1 minute
|
|
Contact resistance
|
50 mΩ or less (Initial values)
|
|
Vibration resistance
|
10 ~ 55 Hz double amplitude 1.5 mm
|
|
Shock resistance
|
Durability
|
300 m/s² or more (30 G or more)
|
|
Malfunction
|
100 m/s² or more (10 G or more)
|
|
Life
|
Mechanical
|
500,000 times or more
|
|
Electrical
|
100,000 times or more (Rated load)
|
|
LAMP Input Power
|
100 - 240 V a.c. / 4.4 VA or less (Voltage drop type LED capacitor)
380 V a.c. / 2.7 VA or less (Voltage drop type LED capacitor)
12 - 24 V d.c. / a.c. / 18 mA or less (LED resistor voltage dropping method)
|
|
Ambient temperature
|
-20 ~ 55 ℃ (Without condensation or icing)
|
|
Ambient humidity
|
45 ~ 85 % RH
|
|
Preservation ambient temperature
|
-40 ~ 70 ℃
|
|
Certification
|
|
※ Only with CRE-25R1R
|
+ CRA
- Illuminated emergency stop switch
|
Model
|
Flat Ø30
|
Flat Ø25
|
|
Appearance
|
|
|
|
Actuator code
|
CRA-30M
|
CRA-25M
|
|
Model
|
Flat Ø30
|
Flat Ø25
|
|
Appearance
|
|
|
|
Actuator code
|
CRA-30R
|
CRA-25R
|
- Specification
|
Contact Structure>
|
M3.5 Threaded, 1a1b
|
|
Contact Behavior
|
Slow-action
|
|
Installation panel thickness
|
1 ~ 6 mm (Without accessories)
|
|
Terminal Tightening Torque
|
0.8 N·m or less
|
|
Rated voltage
|
250 V a.c.
|
|
Current Rating
|
5A 250 V a.c.
|
|
Open/Close Frequency
|
30 times / minute
|
|
Insulation resistance
|
100 MΩ or more (500 V d.c.)
|
|
Dielectric strength
|
1,500 V a.c. 50/60 Hz 1 minute
|
|
Contact resistance
|
50 mΩ or less (Initial values)
|
|
Vibration resistance
|
10 ~ 55 Hz double amplitude 1.5 mm
|
|
Shock resistance
|
Durability
|
300 m/s² or more (30 G or more)
|
|
Malfunction
|
100 m/s² or more (10 G or more)
|
|
Life
|
Mechanical
|
500,000 times or more
|
|
Electrical
|
100,000 times or more (Rated load)
|
|
LAMP Input Power
|
100 - 240 V a.c. / 4.4 VA or less (Voltage drop type LED capacitor)
380 V a.c. / 2.7 VA or less (Voltage drop type LED capacitor)
12 - 24 V d.c. / a.c. / 18 mA or less (LED resistor voltage dropping method)
|
|
Ambient temperature
|
-20 ~ 55 ℃ (Without condensation or icing)
|
|
Ambient humidity
|
45 ~ 85 % RH
|
|
Preservation ambient temperature
|
-40 ~ 70 ℃
|
|
Certification
|
|
+ CRB
- Buzzer
|
Model
|
Flat Ø30
|
Flat Ø25
|
|
Appearance
|
|
|
|
Actuator code
|
CRB-30
|
CRB-25
|
- Specification
|
Contact Structure>
|
M3.5 Threaded, 1a1b
|
|
Contact Behavior
|
Slow-action
|
|
Installation panel thickness
|
1 ~ 6 mm (Without accessories)
|
|
Terminal Tightening Torque
|
0.8 N·m or less
|
|
Rated voltage
|
250 V a.c.
|
|
Current Rating
|
5A 250 V a.c.
|
|
Open/Close Frequency
|
30 times / minute
|
|
Insulation resistance
|
100 MΩ or more (500 V d.c.)
|
|
Dielectric strength
|
1,500 V a.c. 50/60 Hz 1 minute
|
|
Contact resistance
|
50 mΩ or less (Initial values)
|
|
Vibration resistance
|
10 ~ 55 Hz double amplitude 1.5 mm
|
|
Shock resistance
|
Durability
|
300 m/s² or more (30 G or more)
|
|
Malfunction
|
100 m/s² or more (10 G or more)
|
|
Life
|
Mechanical
|
500,000 times or more
|
|
Electrical
|
100,000 times or more (Rated load)
|
|
LAMP Input Power
|
100 - 240 V a.c. / 4.4 VA or less (Voltage drop type LED capacitor)
380 V a.c. / 2.7 VA or less (Voltage drop type LED capacitor)
12 - 24 V d.c. / a.c. / 18 mA or less (LED resistor voltage dropping method)
|
|
Buzzer volume
|
Approx. 90 dB
|
|
Ambient temperature
|
-20 ~ 55 ℃ (Without condensation or icing)
|
|
Ambient humidity
|
45 ~ 85 % RH
|
|
Preservation ambient temperature
|
-40 ~ 70 ℃
|
|
Certification
|
|
+ CR-308
- Selector Push button switch
|
Model
|
Ø30
|
|
Appearance
|
|
|
Actuator code
|
CR-308
|
- Specification
|
Installing Hole
|
Ø30
|
|
Number of Positions
|
2 positions
|
|
Contact Configuration
|
Left / 1a1b, Right / 1a1b
|
|
Contact Rating
|
5A, 250 Va.c.
|
|
Operation Function
|
When the button is pressed after selecting either left or right,
only the contacts of the selected position operate.
|
|
Certification
|
|
|
※ This switch combines the functions of a "selector" and a "push-button."
After selecting either the left or right direction,
pressing the button will operate only the switch in the selected direction.
It is conveniently used in machine tools and automatic control systems.
|
|