LP series LCD display Multi pulse meter
- Improved visibility with the wide viewing angle LCD and white display
- High-speed pulse measurement (50 K㎐)
- IP66 degree of protection
CEEK

The order from the left is the order in which the information is displayed at the bottom. If you cancel the check, the information will be excluded, and if you check, it will be printed out.

print_icon

▍Specifications

Model

LP3

LP6

Power Supply Voltage

100 - 240 V a.c. 50/60 Hz (Voltage fluctuation rate : ±10 %)

Power

consumption

▪LP3-5ANN : Max. 9 VA

▪LP3-5A3RN : Max. 11 VA

▪LP3-5A5RN : Max. 11 VA

▪LP3-5A5NC/5A5PC : Max. 10 VA

▪LP3-5A5NT/5A5PT : Max. 12 VA

▪LP6-5ANN : Max. 8 VA

▪LP6-5A5NN/5A5PN : Max. 9 VA

▪LP6-5A3RN : Max. 9 VA

▪LP6-5ANC : Max. 9 VA

▪LP6-5ANT : Max. 11 VA

Display

▪Negative-LCD ▪4 rows 2 columns ▪PV (white) ▪SV (green)

Character size

▪PV (14.5 mm) ▪SV (10.0 mm)

▪PV (10.5 mm) ▪SV (6.7 mm)

Input Signal

Non-contact (Max. 50 KHz, ON/OFF pulse width Min. 10 us)

Contact (Max. 30 Hz ON/OFF pulse width Min. 16.6 ms)

Input

Voltage

[H] level (4.5 - 24 V d.c.)

[L] level (0 - 1 V d.c.)

Input impedance (4.5 kΩ)

Non-voltage

Impedance during short-circuit (Max. 300 Ω)

Residual voltage (Max. 1 V)

Impedance during open (Min. 100 kΩ)

Measurement range

▪F1, F2, F10, F11, F12, F13 : 0.0005Hz ~ 50KHz

▪F3, F4, F5, F6 : 0.01s ~ 3200s

▪F7, F8, F9 : 0 ~ 99999

Measurement accuracy

▪F1, F2, F10, F11, F12, F13 : F.S. ±0.05% rdg ±1digit

▪F3, F4, F5, F6 : F.S. ±0.01 % rdg ±1digit

External power supply

12 V d.c. ±10 % 100 mA

Display cycle

0.05 s / 0.5 s / 1 sec / 2 sec / 4 sec / 8 sec

Display range

-99999 ~ 99999

Power outagecompensation

Approx. 10 years (non-volatile EEPROM only)

Control

output

3-stage

▪H, L - contact point (SPDT)

▪GO - contact point (SPST)

▪H, GO, L - contact point (SPST)

5-stage

▪HH, H, GO, L, LL - contact point (SPST) or,

Non-contact (NPN or PNP open collector)

*contact point (shared HH/H-COM output and shared LL/L-COM output)

▪HH, H, GO, L, LL - Non-contact

(NPN or PNP open collector)

capacity

▪NO contact (250 V a.c. 5A resistance load)

▪NC contact (250 V a.c. 2A resistance load)

▪Non-contact (12 - 24 V d.c. 50 mA or less)

▪Contact (250 V a.c. 5A resistance load)

▪Non-contact (12 - 24 V d.c. 50 mA or less)

Relay

life cycle

Electrical

Over 100,000 times (250 V a.c. 2A)

Over 100,000 times (250 V a.c. 5A)

Mechanical

More than 10 million times

More than 5 million times

PV transmission output

4 - 20 mA d.c. Load resistance 600 Ω or less (response time 800 ms or less)

RS485 communication output

Communication protocol - Modbus-RTU

Communication method - RS485 (2-wire half duplex)

Communication speed - 2400 / 4800 / 9600 / 19200 / 38400 bps

Vibration durability

10 - 55Hz double amplitude 0.75 mm X, Y, Z each direction, 2 hr

Insulation resistance

Min. 100 MΩ (500 V d.c.), conductive part terminal - Non-conductive metal

Dielectric strength

2,000 V a.c. 60 Hz for 1 minute (between each conductive terminal)

Noise immunity

±2000 V (pulse width l μs, square-wave noise by noise simulator is applied among the power terminals)

Ambient temperature

-10 ~ 50 ℃

Storage temperature

-20 ~ 60 ℃

Ambient humidity

35 ~ 85 % R.H.

protection structure

▪IP66 (front) ▪Terminal block protection cover applied

Certification

CE KC

Weight (excluding box)

150 g

108 g