- Clear status indication with FND display even in dark environments.
- Interfacing with various systems via RS485 communication.
- Maintains a constant current output regardless of input voltage and
load when using constant current control (Communication Type).
- Easy output adjustment through external volume control (Standard Type)
- Equipment protection by overcurrent protection setting in case of abnormal current.
Suffix codeDimensionsSelection GuideNames of Each PartStatus Indication LED DescriptionConnection DiagramTerminal ArrangementAlarm Output DescriptionLoad Current CharacteristicsFunction DescriptionCommunicationInstallation Method and Precautions
The order from the left is the order in which the information is displayed at the bottom.
If you cancel the check, the information will be excluded, and if you check, it will be
printed out.
▍Specification
Classi
fication
Low Voltage
High Voltage
TPR-2F25L□-□□
TPR-2F25H□-□□
TPR-2F35L□-□□
TPR-2F35H□-□□
Output
Voltage
Load Voltage
90 - 240 V a.c.
90 - 480 V a.c.
Circuit Input power
90 - 240 V a.c. 3W (DC Type 24 V d.c. 1W)
Operating Frequency
50/60 Hz (compatible)
Rated current
25A / 35A
Control
Input
Current input
4 - 20 mA d.c. (Impedance : 100Ω) (Optional)
Voltage input
1 - 5 V d.c. (Optional)
Contact input
ON / OFF (Optional)
External V.R
External Variable Resistor (10 kΩ)
(Cannot be used when communication option is selected,
GND position differs between current input and contact input specifications)
Control method
Phase control (Standard), Variable cycle control (Order specification)
*Phase control resolution: 12 bits
Starting method
SOFT START (600 sec), SOFT UP/DOWN (15 sec)
/ Adjustable via SOFT V.R
Output voltage
98% of the power voltage or higher (at maximum current input)
/ Output can be limited with POWER V.R
Alarm
Function
Over current(OC)
RELAY contact output (1 point Normal Open) 1 A, 240 V a.c. / 1A, 30 V d.c.
(NC/NO changeable for communication type)
Heatsink Overheat (OT)
Power Error/
Heater Break (PE)
SCR Short (PE)
Status
Indication
(LED)
Check output volume
FIRE: illuminates in proportion to the output volume
Check
warning
alarms
OC
OC (OVERCURRENT): Lights up when overcurrent occurs / Adjustable via OC V.R
UC (UNDERCURRENT): Blinks when undercurrent occurs (Communication type only)
OT
OT (OVER TEMP): Heat sink temperature 85 ℃ (Optional)
PE
PE (POWER ERROR): Power failure, SCR short
*LB (LOAD BREAK): When load break occurs (Blinking)
Current Display (FND)
2-row Current Display (Display Accuracy: Full Scale ±0.3%, ±1 Digit)
Communication
RS485 MODBUS-RTU (Optional)
Insulation Resistance
100 MΩ or higher (500 V d.c. in megaohms)
Leakage Current
20 mA or lower
Rated impulse
dielectric strength (Uimp)
2,500 V
Output Control Range
0 ~ 100%
Dielectric Strength
2,500 V a.c. (1 minute at 50/60 Hz)
Line Noise
Noise generated by a noise simulator (2,000 V)
Ambient Temperature &
Humidity
-20 ~ 40 ℃, 30 ~ 85% RH (No condensation) ※ Refer to load current characteristic graph