BS series Digital Voltmeter / Ammeter
- Max display 1999
- Measure average value
- Bright and clear LED display

The order from the left is the order in which the information is displayed at the bottom. If you cancel the check, the information will be excluded, and if you check, it will be printed out.

print_icon

▍Specification

Model

BS1

BS3

BS6

Input signal

voltage, current, and instrumentation signal inputs (4 - 20 ㎃ d.c. or 1 - 5 V d.c.)

A/D conversionmethod

Double integration method

Sampling cycle

400 ms

300 ms

Response time

approximately 3 seconds (maximum range)

approximately 2 seconds (maximum range)

External control

Hold function for indication values using contact input

Maximum number of

rows displayed

3½ digit ±1999

Display unit

7-segment LED

Polarity display

If the input signal is reversed

Automatically displays " - " (for DC specs)

 

 

Display of range

underrun

-1□□□ (for DC specifications)

 

 

Measurement and

indication method

Indication of RMS values using full-wave rectification

Precision

AC voltage : ±0.5 % of F.S. ±1 digit

VDC : ±0.2 % of FS ±1 digit

Power voltage

100-240 V a.c. 50/60 ㎐

Allowable voltage fluctuation range : 85 to 110%

110/220 V a.c. 50/60 Hz compatible

24 V d.c. 2.5 W

Voltage fluctuation rate

15 to 10% of power voltage

±10% of power voltage

Power consumption

4 VA or lower

2 VA or lower

Insulation resistance

100 MΩ or higher (500 V d.c. in megaohms), between the external terminal and the casse

Dielectric strength

2000 V a.c. or higher, 1 Min.

between the external terminal and the case

1500 V a.c. for 1 minute, between the external terminal and the case

Vibration resistance

Malfunction : 10 - 55 Hz, single amplitude of 0.5 mm, 1 hour in each direction X· Y· Z

Durability : 10 - 55 Hz, single amplitude of 0.75 mm, 2 hours in each direction X· Y

Shock resistance

Malfunction : 100 m/s2, 3 times in each direction X·Y·Z

Durability : 300 m/s2, 3 times in each direction X·Y·Z

Ambient temperature

-10 to 55 ℃

(however, there should be no icing)

0 to 50 ℃ (however, there should be no icing)

Ambient humidity

relative humidity 35 to 85% R.H.

Storage temperature

-20 to 65 ℃

(however, there should be no icing)

-10 to 70 ℃ (however, there should be no icing)

Weight

150g

350g

250g

▍Suffix code

■ BS1

Model

Code

Content

BS1

Digital Panelmeter

Output

N

 

 

 

Display Only

Input type

A

10

 

AC Voltage input

20

 

AC Current input

D

10

 

DC Voltage input

20

 

DC Current input

11

 

DC Voltage input (1 - 5 V d.c.)

21

 

DC Current input (4 - 20 mA d.c.)

Measurement range

1 - 11

Refer to Measuring Range

■ BS3

Model

Code

Content

BS

Digital Panelmeter

외형

3

 

 

 

 

 

96 (W) X 48 (H) mm

Output

N

 

 

 

 

Only for indication

input type

A

10

 

 

AC voltmeter (AC)

20

 

 

AC ammeter (AC)

D

10

 

 

DC voltmeter (DC)

20

 

 

DC ammeter (DC)

11

 

 

DC voltmeter

21

 

 

DC ammeter

Measurement range

1

 

Refer to Measuring Range.

Power supply voltage

-

110 / 220 V a.c.

D

24 V d.c.

■ BS6

Model

Code

Content

BS6

Digital Panelmeter

Output

N

 

 

 

 

Display Only

Input type

A

10

 

 

AC Voltage input

20

 

 

AC Current input

D

10

 

 

DC Voltage input

20

 

 

DC Current input

11

 

 

DC Voltage input (1 - 5 V d.c.)

21

 

 

DC Current input (4 - 20 mA d.c.)

Measurement range

1 - 11

 

Refer to Measuring Range.

Power supply voltage

No-mark

110/220 V a.c.   50/60 ㎐

D

24 V d.c.

▍Dimension & Panel cutout

[Unit : ㎜]

■ BS1 Dimension

Dimension

■ BS1 Panel cutout

Panel cutout

■ BS3 Dimension

Dimension

■ BS3 Panel cutout

Panel cutout

■ BS6 Dimension

Dimension

■ BS6 Panel cutout

Panel cutout