▍Specification
■ D.C NPN / PNP type
◾ UP8RM / UP8RD / UP12RM / UP12RD
|
Appearance
|
NPN
|
|
|
|
|
|
PNP
|
|
|
|
|
|
Model
|
NPN
|
UP8RM-1.5N□□
|
UP8RD-2N□□
|
UP12RM-2N□□
|
UP12RD-4N□□
|
|
PNP
|
UP8RM-1.5P□□
|
UP8RD-2P□□
|
UP12RM-2P□□
|
UP12RD-4P□□
|
|
Size
|
M8
|
M12
|
|
Shield
|
Shield
|
Non shield
|
Shield
|
Non shield
|
|
Standard sensing object (㎜)
|
Iron 8 X 8 X 1
|
Iron 12 X 12 X 1
|
|
Sensing distance
|
1.5 mm
|
2 mm
|
2 mm
|
4 mm
|
|
Setting distance
|
0 ~ 1.2 mm
|
0 ~ 1.6 mm
|
0 ~ 1.6 mm
|
0 ~ 3.2 mm
|
|
Hysteresis
|
Less than 10 % of sensing distance
|
|
Response frequency
|
800 Hz
|
800 Hz
|
400 Hz
|
|
Power voltage
|
12 V - 24 V d.c. (Usable voltage range 5 - 35 V d.c.)
|
|
Control output
|
Load Current : 200 mA max.
|
|
Residual voltage
|
Max. 1.5 V
|
|
Current consumption
|
Max. 6 mA
|
|
Operation indication
|
Red LED
|
|
protection circuit
|
Power reversely connected protective circuit, surge protective circuit and
over current protective circuit are built in.
|
|
Ambient temperature
|
-25 ~ 70 ℃ (Less than ± 10 % of sensing distance at temperature 20 ℃)
|
|
Ambient humidity
|
35 ~ 85 % R.H.
|
|
Degree of protection
|
IP67 (IEC standard)
|
|
Vibration resistance
|
10 - 55 ㎐ (cycle 1 min), double amplitude : 1.5 ㎜ 2 hours for each of X · Y
· Z directions
|
|
Dielectric strength
|
1500 V a.c. 50 / 60 ㎐ for 1 min (between the recharging part and case)
|
|
Shock resistance
|
500 m/s² 3 times to each, X · Y · Z directions
|
|
Insulation resistance
|
Min. 50 MΩ (500 V d.c. mega standard)
|
|
Connection structure
|
▪Cable type (standard cable length 2 m) ▪Connector Cable type
▪Connector type
|
|
Material
|
▪Case : stainless
▪Sensing surface : PBT
▪Cable holder : polyester elastomer
|
▪Case : brass (chrome plating)
▪Sensing surface : PBT
▪Cable holder : polyester elastomer
|
|
Certification
|
|
|
Weight
|
Cable
|
60g
|
70g
|
|
Connector
Cable type
|
None
|
30g
|
|
Connector
|
None
|
30g
|
◾UP18RM / UP18RD / UP18RLM / UP18RLD
|
Appearance
|
NPN
|
|
|
|
|
|
PNP
|
|
|
|
|
|
Model
|
NPN
|
UP18RM-5N□□
|
UP18RD-8N□□
|
UP18RLM-5N□□
|
UP18RLD-8N□□
|
|
PNP
|
UP18RM-5P□□
|
UP18RD-8P□□
|
UP18RLM-5P□□
|
UP18RLD-8P□□
|
|
Size
|
M18
|
|
Shield
|
Shield
|
Non shield
|
Shield
|
Non shield
|
|
Standard sensing object (㎜)
|
Iron 18 X 18 X 1
|
Iron 25 X 25 X 1
|
Iron 18 X 18 X 1
|
Iron 25 X 25 X 1
|
|
Sensing distance
|
5 mm
|
8 mm
|
5 mm
|
8 mm
|
|
Setting distance
|
0 ~ 4 mm
|
0 ~ 6.4 mm
|
0 ~ 4 mm
|
0 ~ 6.4 mm
|
|
Hysteresis
|
Less than 10 % of sensing distance
|
|
Response frequency
|
350 Hz
|
200 Hz
|
350 Hz
|
200 Hz
|
|
Power voltage
|
12 V - 24 V d.c. (Usable voltage range 5 - 35 V d.c.)
|
|
Control output
|
Load Current : 200 mA max.
|
|
Residual voltage
|
Max. 1.5 V
|
|
Current consumption
|
Max. 6 mA
|
|
Operation indication
|
Red LED
|
|
protection circuit
|
Power reversely connected protective circuit, surge protective circuit and
over current protective circuit are built in.
|
|
Ambient temperature
|
-25 ~ 70 ℃ (Less than ± 10 % of sensing distance at temperature 20 ℃)
|
|
Ambient humidity
|
35 ~ 85 % R.H.
|
|
Degree of protection
|
IP67 (IEC standard)
|
|
Vibration resistance
|
10 - 55 ㎐ (cycle 1 min), double amplitude : 1.5 ㎜ 2 hours for each of X · Y
· Z directions
|
|
Dielectric strength
|
1500 V a.c. 50 / 60 ㎐ for 1 min (between the recharging part and case)
|
|
Shock resistance
|
500 m/s² 3 times to each, X · Y · Z directions
|
|
Insulation resistance
|
Min. 50 MΩ (500 V d.c. mega standard)
|
|
Connection structure
|
▪Cable type (standard cable length 2 m) ▪Connector Cable type
▪Connector type
|
|
Material
|
▪Case : brass (chrome plating) ▪Sensing surface : PBT
▪Cable holder : polyester elastomer
|
|
Certification
|
|
|
Weight
|
Cable
|
120g
|
140g
|
|
Connector
Cable type
|
80g
|
100g
|
|
Connector
|
60g
|
80g
|
◾ UP30RM / UP30RD / UP30RLM / UP30RLD
|
Appearance
|
NPN
|
|
|
|
|
|
PNP
|
|
|
|
|
|
Model
|
NPN
|
UP30RM-10N□□
|
UP30RD-15N□□
|
UP30RLM-10N□□
|
UP30RLD-15N□□
|
|
PNP
|
UP30RM-10P□□
|
UP30RD-15P□□
|
UP30RLM-10P□□
|
UP30RLD-15P□□
|
|
Size
|
M30
|
|
Shield
|
Shield
|
Non shield
|
Shield
|
Non shield
|
|
Standard sensing object (㎜)
|
Iron 30 X 30 X 1
|
Iron 45 X 45 X 1
|
Iron 30 X 30 X 1
|
Iron 45 X 45 X 1
|
|
Sensing distance
|
10 mm
|
15 mm
|
10 mm
|
15 mm
|
|
Setting distance
|
0 ~ 8 mm
|
0 ~ 12 mm
|
0 ~ 8 mm
|
0 ~ 12 mm
|
|
Hysteresis
|
Less than 10% of sensing distance
|
|
Response frequency
|
250 Hz
|
100 Hz
|
250 Hz
|
100 Hz
|
|
Power voltage
|
12 V - 24 V d.c. (Usable voltage range 5 - 35 V d.c.)
|
|
Control output
|
Load Current : 200 mA max.
|
|
Residual voltage
|
Max. 1.5 V
|
|
Current consumption
|
Max. 6 mA
|
|
Operation indication
|
Red LED
|
|
protection circuit
|
Power reversely connected protective circuit, surge protective circuit and
over current protective circuit are built in.
|
|
Ambient temperature
|
-25 ~ 70 ℃ (Less than ±10 % of sensing distance at temperature 20 ℃)
|
|
Ambient humidity
|
35 ~ 85 % R.H.
|
|
Degree of protection
|
IP67 (IEC standard)
|
|
Vibration resistance
|
10 - 55 ㎐ (cycle 1 min), double amplitude : 1.5 ㎜ 2 hours for each of X · Y
· Z directions
|
|
Dielectric strength
|
1500 V a.c. 50 / 60 ㎐ for 1 min (between the recharging part and case)
|
|
Shock resistance
|
500 m/s² 3 times to each, X · Y · Z directions
|
|
Insulation resistance
|
Min. 50 MΩ (500 V d.c. mega standard)
|
|
Connection structure
|
▪Cable type (standard cable length 2 m) ▪Connector Cable type
▪Connector type
|
|
Material
|
▪Case : brass (chrome plating) ▪Sensing surface : PBT
▪Cable holder : polyester elastomer
|
|
Certification
|
|
|
Weight
|
Cable
|
170g
|
220g
|
|
Connector
Cable type
|
130g
|
180g
|
|
Connector
|
150g
|
200g
|
■ D.C 2wire type
◾ UP8RM / UP8RD / UP12RM / UP12RD
|
Appearance
|
N.O
|
|
|
|
|
|
N.C
|
|
|
|
|
|
Model
|
Polar
|
UP8RM-1.5T□□
|
UP8RD-2TT□□
|
UP12RM-2T□□
|
UP12RD-4T□□
|
|
No polarity
|
-
|
-
|
UP12RM-2U□□
|
UP12RD-4U□□
|
|
Size
|
M8
|
M12
|
|
Shield
|
Shield
|
Non shield
|
Shield
|
Non shield
|
|
Standard sensing object (㎜)
|
Iron 8 X 8 X 1
|
Iron 12 X 12 X 1
|
|
Sensing distance
|
1.5 mm
|
2 mm
|
2 mm
|
4 mm
|
|
Setting distance
|
0 ~ 1.2 mm
|
0 ~ 1.6 mm
|
0 ~ 1.6 mm
|
0 ~ 3.2 mm
|
|
Hysteresis
|
Less than 10 % of sensing distance
|
|
Response frequency
|
800 Hz
|
800 Hz
|
400 Hz
|
|
Power voltage
|
12 V - 24 V d.c. (Usable voltage range 10 - 30 V d.c.)
|
|
Control output
|
Load Current : 100 mA max.
|
|
Residual voltage
|
▪T (Polarity) : max. 3.5 V, ▪U (no polarity) : 5 V max.
|
|
Current consumption
|
Max. 1 mA
|
|
Operation indication
|
Red LED
|
|
protection circuit
|
Surge protective circuit and over current protective circuit are built-in.
|
|
Ambient temperature
|
-25 ~ 70 ℃ (Less than ±10 % of sensing distance at temperature 20 ℃)
|
|
Ambient humidity
|
35 ~ 85 % R.H.
|
|
Degree of protection
|
IP67 (IEC standard)
|
|
Vibration resistance
|
10 - 55 ㎐ (cycle 1 min), double amplitude : 1.5 ㎜ 2 hours for each of X · Y
· Z directions
|
|
Dielectric strength
|
1500 V a.c. 50 / 60 ㎐ for 1 min (between the recharging part and case)
|
|
Shock resistance
|
500 m/s² 3 times to each, X · Y · Z directions
|
|
Insulation resistance
|
Min. 50 MΩ (500 V d.c. mega standard)
|
|
Connection structure
|
▪Cable type (standard cable length 2 m) ▪Connector Cable type
▪Connector type
|
|
Material
|
▪Case : brass (chrome plating)
▪Sensing surface : PBT
▪Cable holder : polyester elastomer
|
▪Case : brass (chrome plating) ▪Sensing surface : PBT
▪Cable holder : polyester elastomer
|
|
Certification
|
|
|
Weight
|
Cable
|
60g
|
70g
|
|
Connector
Cable type
|
None
|
50g
|
|
Connector
|
None
|
30g
|
◾ UP18RM / UP18RD / UP18RLM / UP18RLD
|
Appearance
|
N.O
|
|
|
|
|
|
N.C
|
|
|
|
|
|
Model
|
Polar
|
UP18RM-5T□□
|
UP18RD-8T□□
|
UP18RLM-5T□□
|
UP18RLD-8T□□
|
|
No polarity
|
UP18RM-5U□□
|
UP18RD-8U□□
|
UP18RLM-5U□□
|
UP18RLD-8U□□
|
|
Size
|
M18
|
|
Shield
|
Shield
|
Non shield
|
Shield
|
Non shield
|
|
Standard sensing object (㎜)
|
Iron 18 X 18 X 1
|
Iron 25 X 25 X 1
|
Iron 18 X 18 X 1
|
Iron 25 X 25 X 1
|
|
Sensing distance
|
5 mm
|
8 mm
|
5 mm
|
8 mm
|
|
Setting distance
|
0 ~ 4 mm
|
0 ~ 6.4 mm
|
0 ~ 4 mm
|
0 ~ 6.4 mm
|
|
Hysteresis
|
Less than 10 % of sensing distance
|
|
Response frequency
|
350 Hz
|
200 Hz
|
350 Hz
|
200 Hz
|
|
Power voltage
|
12 V - 24 V d.c. (Usable voltage range 10 - 30 V d.c.)
|
|
Control output
|
Load Current : 100 mA max.
|
|
Residual voltage
|
▪T (Polarity) : max. 3.5 V ▪U (No polarity) : max. 5 V
|
|
Current consumption
|
Max. 1 mA
|
|
Operation indication
|
Red LED
|
|
protection circuit
|
Surge protective circuit and over current protective circuit are built-in.
|
|
Ambient temperature
|
-25 ~ 70 ℃ (Less than ±10 % of sensing distance at temperature 20 ℃)
|
|
Ambient humidity
|
35 ~ 85 % R.H.
|
|
Degree of protection
|
IP67 (IEC standard)
|
|
Vibration resistance
|
10 - 55 ㎐ (cycle 1 min), double amplitude : 1.5 ㎜ 2 hours for each of X · Y
· Z directions
|
|
Dielectric strength
|
1500 V a.c. 50 / 60 ㎐ for 1 min (between the recharging part and case)
|
|
Shock resistance
|
500 m/s² 3 times to each, X · Y · Z directions
|
|
Insulation resistance
|
Min. 50 MΩ (500 V d.c. mega standard)
|
|
Connection structure
|
▪Cable type (standard cable length 2 m) ▪Connector Cable type
▪Connector type
|
|
Material
|
▪Case : brass (chrome plating) ▪Sensing surface : PBT
▪Cable holder : polyester elastomer
|
|
Certification
|
|
|
Weight
|
Cable
|
120g
|
140g
|
|
Connector
Cable type
|
80g
|
100g
|
|
Connector
|
60g
|
80g
|
◾ UP30RM / UP30RD / UP30RLM / UP30RLD
|
Appearance
|
N.O
|
|
|
|
|
|
N.C
|
|
|
|
|
|
Model
|
Polar
|
UP30RM-10T□□
|
UP30RD-15T□□
|
UP30RLM-10T□□
|
UP30RLD-15T□□
|
|
No polarity
|
UP30RM-10U□□
|
UP30RD-15U□□
|
UP30RLM-10U□□
|
UP30RLD-15U□□
|
|
Size
|
M30
|
|
Shield
|
Shield
|
Non shield
|
Shield
|
Non shield
|
|
Standard sensing object (㎜)
|
Iron 30 X 30 X 1
|
Iron 45 X 45 X 1
|
Iron 30 X 30 X 1
|
Iron 45 X 45 X 1
|
|
Sensing distance
|
10 mm
|
15 mm
|
10 mm
|
15 mm
|
|
Setting distance
|
0 ~ 8 mm
|
0 ~ 12 mm
|
0 ~ 8 mm
|
0 ~ 12 mm
|
|
Hysteresis
|
Less than 10 % of sensing distance
|
|
Response frequency
|
250 Hz
|
100 Hz
|
250 Hz
|
100 Hz
|
|
Power voltage
|
12 V - 24 V d.c. (Usable voltage range 10 - 30 V d.c.)
|
|
Control output
|
Load Current : 100 mA max.
|
|
Residual voltage
|
▪T (Polarity) : max. 3.5 V ▪U (No polarity) : max. 5 V
|
|
Current consumption
|
Max. 1 mA
|
|
Operation indication
|
Red LED
|
|
protection circuit
|
Surge protective circuit and over current protective circuit are built-in.
|
|
Ambient temperature
|
-25 ~ 70 ℃ (Less than ±10 % of sensing distance at temperature 20 ℃)
|
|
Ambient humidity
|
35 ~ 85 % R.H.
|
|
Degree of protection
|
IP67 (IEC standard)
|
|
Vibration resistance
|
10 - 55 ㎐ (cycle 1 min), double amplitude : 1.5 ㎜ 2 hours for each of X · Y
· Z directions
|
|
Dielectric strength
|
1500 V a.c. 50 / 60 ㎐ for 1 min (between the recharging part and case)
|
|
Shock resistance
|
500 m/s² 3 times to each, X · Y · Z directions
|
|
Insulation resistance
|
Min. 50 MΩ (500 V d.c. mega standard)
|
|
Connection structure
|
▪Cable type (standard cable length 2 m) ▪Connector Cable type
▪Connector type
|
|
Material
|
▪Case : brass (chrome plating) ▪Sensing surface : PBT
▪Cable holder : polyester elastomer
|
|
Certification
|
|
|
Weight
|
Cable
|
170g
|
220g
|
|
Connector
Cable type
|
130g
|
180g
|
|
Connector
|
150g
|
200g
|
■ A.C 2wire Type
◾ UP12RM / UP12RD
|
Appearance
|
N.O
|
|
|
|
N.C
|
|
|
|
Model
|
AC type
|
UP12RM-2A□□
|
UP12RD-4A□□
|
|
Size
|
M12
|
|
Shield
|
Shield
|
Non shield
|
|
Standard sensing object (㎜)
|
Iron 12 X 12 X 1
|
|
Sensing distance
|
2 mm
|
4 mm
|
|
Setting distance
|
0 ~ 1.6 mm
|
0 ~ 3.2 mm
|
|
Hysteresis
|
Less than 10 % of sensing distance
|
|
Response frequency
|
20 Hz
|
|
Power voltage
|
100 V - 240 V a.c. (Usable voltage range 90 - 250 V a.c.)
|
|
Control output
|
Load Current : 200 mA max.
|
|
Residual voltage
|
Max. 10 V
|
|
Current consumption
|
Max. 2.2 mA
|
|
Operation indication
|
Red LED
|
|
protection circuit
|
surge protective circuit built in.
|
|
Ambient temperature
|
-25 ~ 70 ℃ (Less than ±10 % of sensing distance at temperature 20 ℃)
|
|
Ambient humidity
|
35 ~ 85 % R.H.
|
|
Degree of protection
|
IP67 (IEC standard)
|
|
Vibration resistance
|
10 - 55 ㎐ (cycle 1 min), double amplitude : 1.5 ㎜ 2 hours for each of X · Y
· Z directions
|
|
Dielectric strength
|
For 1 min at 2000 V a.c. 50 / 60 ㎐ (between the recharging part and case)
|
|
Shock resistance
|
500 m/s² 3 times to each, X · Y · Z directions
|
|
Insulation resistance
|
Min. 50 MΩ (500 V d.c. mega standard)
|
|
Connection structure
|
▪Cable type (standard cable length 2 m) ▪Connector Cable type
▪Connector type
|
|
Material
|
▪Case : brass (chrome plating) ▪Sensing surface : PBT
▪Cable holder : polyester elastomer
|
|
Certification
|
|
|
Weight
|
Cable
|
70g
|
|
Connector
Cable type
|
30g
|
|
Connector
|
30g
|
◾ UP18RM / UP18RD / UP18RLM / UP18RLD
|
Appearance
|
N.O
|
|
|
|
|
|
N.C
|
|
|
|
|
|
Model
|
AC type
|
UP18RM-5A□□
|
UP18RD-8A□□
|
UP18RLM-5A□□
|
UP18RLD-8A□□
|
|
Size
|
M18
|
|
Shield
|
Shield
|
Non shield
|
Shield
|
Non shield
|
|
Standard sensing object (㎜)
|
Iron 18 X 18 X 1
|
Iron 25 X 25 X 1
|
Iron 18 X 18 X 1
|
Iron 25 X 25 X 1
|
|
Sensing distance
|
5 mm
|
8 mm
|
5 mm
|
8 mm
|
|
Setting distance
|
0 ~ 4 mm
|
0 ~ 6.4 mm
|
0 ~ 4 mm
|
0 ~ 6.4 mm
|
|
Hysteresis
|
Less than 10 % of sensing distance
|
|
Response frequency
|
20 Hz
|
|
Power voltage
|
100 V - 240 V a.c. (Usable voltage range 90 - 250 V a.c.)
|
|
Control output
|
Load Current : 200 mA max.
|
|
Residual voltage
|
Max. 10 V
|
|
Current consumption
|
Max. 2.2 mA
|
|
Operation indication
|
Red LED
|
|
protection circuit
|
surge protective circuit built in.
|
|
Ambient temperature
|
-25 ~ 70 ℃ (Less than ±10 % of sensing distance at temperature 20 ℃)
|
|
Ambient humidity
|
35 ~ 85 % R.H.
|
|
Degree of protection
|
IP67 (IEC standard)
|
|
Vibration resistance
|
10 - 55 ㎐ (cycle 1 min), double amplitude : 1.5 ㎜ 2 hours for each of X · Y
· Z directions
|
|
Dielectric strength
|
For 1 min at 2000 V a.c. 50 / 60 ㎐ (between the recharging part and case)
|
|
Shock resistance
|
500 m/s² 3 times to each, X · Y · Z directions
|
|
Insulation resistance
|
Min. 50 MΩ (500 V d.c. mega standard)
|
|
Connection structure
|
▪Cable type (standard cable length 2 m) ▪Connector Cable type
▪Connector type
|
|
Material
|
▪Case : brass (chrome plating) ▪Sensing surface : PBT
▪Cable holder : polyester elastomer
|
|
Certification
|
|
|
Weight
|
Cable
|
120g
|
140g
|
|
Connector
Cable type
|
80g
|
100g
|
|
Connector
|
60g
|
80g
|
◾ UP30RM / UP30RD / UP30RLM / UP30RLD
|
Appearance
|
N.O
|
|
|
|
|
|
N.C
|
|
|
|
|
|
Model
|
AC type
|
UP30RM-10A□□
|
UP30RD-15A□□
|
UP30RLM-10A□□
|
UP30RLD-15A□□
|
|
Size
|
M30
|
M30
|
|
Shield
|
Shield
|
Non shield
|
Shield
|
Non shield
|
|
Standard sensing object (㎜)
|
Iron 30 X 30 X 1
|
Iron 45 X 45 X 1
|
Iron 30 X 30 X 1
|
Iron 45 X 45 X 1
|
|
Sensing distance
|
10 mm
|
15 mm
|
10 mm
|
15 mm
|
|
Setting distance
|
0 ~ 8 mm
|
0 ~ 12 mm
|
0 ~ 8 mm
|
0 ~ 12 mm
|
|
Hysteresis
|
Less than 10 % of sensing distance
|
|
Response frequency
|
20 Hz
|
|
Power voltage
|
100 V - 240 V a.c. (Usable voltage range 90 - 250 V a.c.)
|
|
Control output
|
Load Current : 200 mA max.
|
|
Residual voltage
|
Max. 10 V
|
|
Current consumption
|
Max. 2.2 mA
|
|
Operation indication
|
Red LED
|
|
protection circuit
|
surge protective circuit built in.
|
|
Ambient temperature
|
-25 ~ 70 ℃ (Less than ±10 % of sensing distance at temperature 20 ℃)
|
|
Ambient humidity
|
35 ~ 85 % R.H.
|
|
Degree of protection
|
IP67 (IEC standard)
|
|
Vibration resistance
|
10 - 55 ㎐ (cycle 1 min), double amplitude : 1.5 ㎜ 2 hours for each of X · Y
· Z directions
|
|
Dielectric strength
|
For 1 min at 2000 V a.c. 50 / 60 ㎐ (between the recharging part and case)
|
|
Shock resistance
|
500 m/s² 3 times to each, X · Y · Z directions
|
|
Insulation resistance
|
Min. 50 MΩ (500 V d.c. mega standard)
|
|
Connection structure
|
▪Cable type (standard cable length 2 m) ▪Connector Cable type
▪Connector type
|
|
Material
|
▪Case : brass (chrome plating) ▪Sensing surface : PBT
▪Cable holder : polyester elastomer
|
|
Certification
|
|
|
Weight
|
Cable
|
170g
|
220g
|
|
Connector
Cable type
|
130g
|
180g
|
|
Connector
|
150g
|
200g
|
|