▍Specification
■ DC 3 wire type
|
Model
|
NPN
|
UP12S-4N□□
|
UP18S-5N□□
|
UP18S-8N□□
|
|
PNP
|
UP12S-4P□□
|
UP18S-5P□□
|
UP18S-8P□□
|
|
Appearance
|
 |
 |
|
Sensing distance
|
4 mm
|
5 mm
|
8 mm
|
|
Setting distance
|
0 - 3.2 mm
|
0 - 4 mm
|
0 - 6.4 mm
|
|
Response frequency
|
800 Hz
|
800 Hz
|
250 Hz
|
|
Standard sensing object (mm)
|
Iron 12 × 12 × 1
|
Iron 18 X 18 X 1
|
Iron 25 X 25 X 1
|
|
Hysteresis
|
Less than 10 % of sensing distance
|
|
Power supply voltage
|
12 V - 24 V d.c. (5 - 35 V d.c.)
|
|
Control output
|
Resistive load : 200 mA max.
|
|
Residual voltage
|
1.5 V max
|
|
Current consumption
|
6 mA max
|
|
Operation indication
|
Red LED
|
|
Protective circuit
|
Power reversely connected protective circuit, surge protective circuit and over current
protective circuit are built in.
|
|
Ambient temperature
|
-25 ~ 70 ℃ (Less than ±10 % of sensing distance at temperature 20 ℃)
|
|
Ambient humidity
|
35 ~ 85 % R.H
|
|
Degree of protection
|
IP67 (IEC standard)
|
|
Vibration resistance
|
10 - 55 ㎐ (cycle 1 min), double amplitude : 1.5 ㎜ 2 hours for each of X · Y · Z directions
|
|
Dielectric strength
|
For 1 min at 2000 V a.c. 50/60 Hz (between the recharging part and case)
|
|
Shock resistance
|
500 m/s² 3 times to each, X · Y · Z directions
|
|
Insulation resistance
|
50 MΩ min (500 V d.c. mega standard)
|
|
Material
|
CASE : PBT resin
|
|
Certification
|
|
※ Only with UP-18S-5NA, UP-18S-5PA
|
■ DC 3 wire type
|
Model
|
NPN
|
UP25S-5N□□
|
UP25S-8N□□
|
UP25S-12N□□
|
|
PNP
|
UP25S-5P□□
|
UP25S-8P□□
|
UP25S-12P□□
|
|
Appearance
|
|
|
Sensing distance
|
5 mm
|
8 mm
|
12 mm
|
|
Setting distance
|
0 - 4 mm
|
0 - 6.4 mm
|
0 - 9.6 mm
|
|
Response frequency
|
350 Hz
|
250 Hz
|
200 Hz
|
|
Standard sensing object (mm)
|
Iron 25 X 25 X 1
|
Iron 25 X 25 X 1
|
Iron 35 X 35 X 1
|
|
Hysteresis
|
Less than 10 % of sensing distance
|
|
Power supply voltage
|
12 V - 24 V d.c. (5 - 35 V d.c.)
|
|
Control output
|
Resistive load : 200 mA max.
|
|
Residual voltage
|
1.5 V max
|
|
Current consumption
|
6 mA max
|
|
Operation indication
|
Red LED
|
|
Protective circuit
|
Power reversely connected protective circuit, surge protective circuit and over current
protective circuit are built in.
|
|
Ambient temperature
|
-25 ~ 70 ℃ (Less than ±10 % of sensing distance at temperature 20 ℃)
|
|
Ambient humidity
|
35 ~ 85 % R.H
|
|
Degree of protection
|
IP67 (IEC standard)
|
|
Vibration resistance
|
10 - 55 ㎐ (cycle 1 min), double amplitude : 1.5 ㎜ 2 hours for each of X · Y · Z directions
|
|
Dielectric strength
|
For 1 min at 2000 V a.c. 50/60 Hz (between the recharging part and case)
|
|
Shock resistance
|
500 m/s² 3 times to each, X · Y · Z directions
|
|
Insulation resistance
|
50 MΩ min (500 V d.c. mega standard)
|
|
Material
|
CASE : PBT resin
|
|
Certification
|
|
■ DC 3 wire type
|
Model
|
NPN
|
UP30S-10N□□
|
UP30S-15N□□
|
UP40S-20N□□
|
|
PNP
|
UP30S-10P□□
|
UP30S-15P□□
|
UP40S-20P□□
|
|
Appearance
|
|
 |
|
Sensing distance
|
10 mm
|
15 mm
|
20 mm
|
|
Setting distance
|
0 - 8 mm
|
0 - 12 mm
|
0 - 16 mm
|
|
Response frequency
|
250 Hz
|
100 Hz
|
100 Hz
|
|
Standard sensing object (mm)
|
Iron 30 X 30 X 1
|
Iron 45 X 45 X 1
|
Iron 60 X 60 X 1
|
|
Hysteresis
|
Less than 10 % of sensing distance
|
|
Power supply voltage
|
12 V - 24 V d.c. (5 - 35 V d.c.)
|
|
Control output
|
Resistive load : 200 mA max.
|
|
Residual voltage
|
1.5 V max
|
|
Current consumption
|
6 mA max
|
|
Operation indication
|
Red LED
|
|
Protective circuit
|
Power reversely connected protective circuit, surge protective circuit and over current
protective circuit are built in.
|
|
Ambient temperature
|
-25 ~ 70 ℃ (Less than ±10 % of sensing distance at temperature 20 ℃)
|
|
Ambient humidity
|
35 ~ 85 % R.H
|
|
Degree of protection
|
IP67 (IEC standard)
|
|
Vibration resistance
|
10 - 55 ㎐ (cycle 1 min), double amplitude : 1.5 ㎜ 2 hours for each of X · Y · Z directions
|
|
Dielectric strength
|
For 1 min at 2000 V a.c. 50/60 Hz (between the recharging part and case)
|
|
Shock resistance
|
500 m/s² 3 times to each, X · Y · Z directions
|
|
Insulation resistance
|
50 MΩ min (500 V d.c. mega standard)
|
|
Material
|
CASE : PBT resin
|
|
Certification
|
|
■ DC 2 wire type
|
Model
|
Polar
|
UP12S-4T□□
|
UP18S-5T□□
|
UP18S-8T□□
|
|
No polarity
|
UP12S-4U□□
|
UP18S-5U□□
|
UP18S-8U□□
|
|
Appearance
|
 |
|
|
Sensing distance
|
4 mm
|
5 mm
|
8 mm
|
|
Setting distance
|
0 - 3.2 mm
|
0 - 4 mm
|
0 - 6.4 mm
|
|
Response frequency
|
500 Hz
|
500 Hz
|
300 Hz
|
|
Standard sensing object (mm)
|
Iron 12 × 12 × 1
|
Iron 18 X 18 X 1
|
Iron 25 X 25 X 1
|
|
Hysteresis
|
Less than 10 % of sensing distance
|
|
Power supply voltage
|
12 V - 24 V d.c. (10 - 30 V d.c.)
|
|
Control output
|
Resistive load : 100 mA max.
|
|
Residual voltage
|
▪T (Polarity) : 3.5 V max, ▪U (No polarity) : 5 V max
|
|
Leakage current
|
1 mA max
|
|
Operation indication
|
Red LED
|
|
Protective circuit
|
surge protective circuit and over current protective circuit are built in.
|
|
Ambient temperature
|
-25 ~ 70 ℃ (Less than ±10 % of sensing distance at temperature 20 ℃)
|
|
Ambient humidity
|
35 ~ 85 % R.H
|
|
Degree of protection
|
IP67 (IEC standard)
|
|
Vibration resistance
|
10 - 55 ㎐ (cycle 1 min), double amplitude : 1.5 ㎜ 2 hours for each of X · Y · Z directions
|
|
Dielectric strength
|
For 1 min at 2000 V a.c. 50/60 Hz (between the recharging part and case)
|
|
Shock resistance
|
500 m/s² 3 times to each, X · Y · Z directions
|
|
Insulation resistance
|
50 MΩ min (500 V d.c. mega standard)
|
|
Material
|
CASE : PBT resin
|
|
Certification
|
|
※ Only with UP-18S-5TC
|
■ DC 2 wire type
|
Model
|
Polar
|
UP25S-5T□□
|
UP25S-8T□□
|
UP25S-12T□□
|
|
No polarity
|
UP25S-5U□□
|
UP25S-8U□□
|
UP25S-12U□□
|
|
Appearance
|
|
|
Sensing distance
|
5 mm
|
8 mm
|
12 mm
|
|
Setting distance
|
0 - 4 ㎜
|
0 - 6.4 ㎜
|
0 - 9.6 ㎜
|
|
Response frequency
|
350 Hz
|
250 Hz
|
200 Hz
|
|
Standard sensing object (mm)
|
Iron 25 X 25 X 1
|
Iron 25 X 25 X 1
|
Iron 35 X 35 X 1
|
|
Hysteresis
|
Less than 10 % of sensing distance
|
|
Power supply voltage
|
12 V - 24 V d.c. (10 - 30 V d.c.)
|
|
Control output
|
Resistive load : 100 mA max.
|
|
Residual voltage
|
▪T (Polarity) : 3.5 V max, ▪U (No polarity) : 5 V max
|
|
Leakage current
|
1 mA max
|
|
Operationindication
|
Red LED
|
|
Protective circuit
|
surge protective circuit and over current protective circuit are built in.
|
|
Ambient temperature
|
-25 ~ 70 ℃ (Less than ±10 % of sensing distance at temperature 20 ℃)
|
|
Ambient humidity
|
35 ~ 85 % R.H
|
|
Degree of protection
|
IP67 (IEC standard)
|
|
Vibration resistance
|
10 - 55 ㎐ (cycle 1 min) double amplitude : 1.5 ㎜ 2 hours for each of X · Y · Z directions
|
|
Dielectric strength
|
For 1 min at 2000 V a.c. 50/60 Hz (between the recharging part and case)
|
|
Shock resistance
|
500 m/s² 3 times to each, X · Y · Z directions
|
|
Insulation resistance
|
50 MΩ min (500 V d.c. mega standard)
|
|
Material
|
CASE : PBT resin
|
|
Certification
|
|
■ DC 2 wire type
|
Model
|
Polar
|
UP30S-10T□□
|
UP30S-15T□□
|
UP40S-20T□□
|
|
No polarity
|
UP30S-10U□□
|
UP30S-15U□□
|
UP40S-20U□□
|
|
Appearance
|
|
 |
|
Sensing distance
|
10 mm
|
15 mm
|
20 mm
|
|
Setting distance
|
0 - 8 ㎜
|
0 - 12 ㎜
|
0 - 16 ㎜
|
|
Response frequency
|
250 Hz
|
100 Hz
|
100 Hz
|
|
Standard sensing object (mm)
|
Iron 30 X 30 X 1
|
Iron 45 X 45 X 1
|
Iron 60 X 60 X 1
|
|
Hysteresis
|
Less than 10 % of sensing distance
|
|
Power supply voltage
|
12 V - 24 V d.c. (10 - 30 V d.c.)
|
|
Control output
|
Resistive load : 100 mA max.
|
|
Residual voltage
|
▪T (Polarity) : 3.5 V max, ▪U (No polarity) : 5 V max
|
|
Leakage current
|
1 mA max
|
|
Operationindication
|
Red LED
|
|
Protective circuit
|
surge protective circuit and over current protective circuit are built in.
|
|
Ambient temperature
|
-25 ~ 70 ℃ (Less than ±10 % of sensing distance at temperature 20 ℃)
|
|
Ambient humidity
|
35 ~ 85 % R.H
|
|
Degree of protection
|
IP67 (IEC standard)
|
|
Vibration resistance
|
10 - 55 ㎐ (cycle 1 min) double amplitude : 1.5 ㎜ 2 hours for each of X · Y · Z directions
|
|
Dielectric strength
|
For 1 min at 2000 V a.c. 50/60 Hz (between the recharging part and case)
|
|
Shock resistance
|
500 m/s² 3 times to each, X · Y · Z directions
|
|
Insulation resistance
|
50 MΩ min (500 V d.c. mega standard)
|
|
Material
|
CASE : PBT resin
|
|
Certification
|
|
■ AC 2 wire type
|
Model
|
For AC
|
UP25S-5A□□
|
UP25S-8A□□
|
|
Appearance
|
 |
|
Sensing distance
|
5 ㎜
|
8 ㎜
|
|
Setting distance
|
0 - 4 ㎜
|
0 - 6.4 ㎜
|
|
Response frequency
|
20 ㎐
|
|
Standard sensing object (㎜)
|
Iron 25 x 25 x 1
|
Iron 30 x 30 x 1
|
|
Hysteresis
|
Less than 10 % of sensing distance
|
|
Power supply voltage
|
100 - 240 V a.c. (90 - 250 V a.c.)
|
|
Control output
|
Resistive load : 200 mA max.
|
|
Residual voltage
|
10 V a.c. max
|
|
Leakage current
|
2.2 mA max
|
|
Operation indication
|
Red LED
|
|
Protective circuit
|
surge protective circuit built in.
|
|
Ambient temperature
|
-25 ~ 70 ℃ (Less than ±10 % of sensing distance at temperature 20 ℃)
|
|
Ambient humidity
|
35 ~ 85 % R.H
|
|
Degree of protection
|
IP67 (IEC standard)
|
|
Vibration resistance
|
10 - 55 ㎐ (cycle 1 min), double amplitude : 1.5 ㎜ 2 hours for each of X · Y · Z directions
|
|
Dielectric strength
|
For 1 min at 2000 V a.c. 50/60 Hz (between the recharging part and case)
|
|
Shock resistance
|
500 m/s² 3 times to each, X · Y · Z directions
|
|
Insulation resistance
|
50 MΩ min (500 V d.c. mega standard)
|
|
Material
|
CASE : PBT resin
|
|
Certification
|
|
■ AC 2 wire type
|
Model
|
For AC
|
UP30S-10A□□
|
UP30S-15A□□
|
UP40S-20A□□
|
|
Appearance
|
|
|
|
Sensing distance
|
10 ㎜
|
15 ㎜
|
20 ㎜
|
|
Setting distance
|
0 - 8 ㎜
|
0 - 12 ㎜
|
0 - 16 ㎜
|
|
Response frequency
|
20 ㎐
|
|
Standard sensing object (㎜)
|
Iron 40 x 40 x 1
|
Iron 50 x 50 x 1
|
Iron 60 x 60 x 1
|
|
Hysteresis
|
Less than 10 % of sensing distance
|
|
Power supply voltage
|
100 - 240 V a.c. (90 - 250 V a.c.)
|
|
Control output
|
Resistive load : 200 mA max.
|
|
Residual voltage
|
10 V a.c. max
|
|
Leakage current
|
2.2 mA max
|
|
Operation indication
|
Red LED
|
|
Protective circuit
|
surge protective circuit built in.
|
|
Ambient temperature
|
-25 ~ 70 ℃ (Less than ±10 % of sensing distance at temperature 20 ℃)
|
|
Ambient humidity
|
35 ~ 85 % R.H
|
|
Degree of protection
|
IP67 (IEC standard)
|
|
Vibration resistance
|
10 - 55 ㎐ (cycle 1 min), double amplitude : 1.5 ㎜ 2 hours for each of X · Y · Z directions
|
|
Dielectric strength
|
For 1 min at 2000 V a.c. 50/60 Hz (between the recharging part and case)
|
|
Shock resistance
|
500 m/s² 3 times to each, X · Y · Z directions
|
|
Insulation resistance
|
50 MΩ min (500 V d.c. mega standard)
|
|
Material
|
CASE : PBT resin
|
|
Certification
|
|
|